Swimming Pool Heater with V Shape Design High Efficiency Evaporator

Product Details
Customization: Available
Certification: CE
Heat Source Type: Air Source Heat Pump
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2005

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Importers and Exporters
The supplier has import and export rights
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Experienced Team
The supplier has 10 foreign trading staff(s) and 9 staff(s) with over 6 years of overseas trading experience
to see all verified strength labels (29)
  • Swimming Pool Heater with V Shape Design High Efficiency Evaporator
  • Swimming Pool Heater with V Shape Design High Efficiency Evaporator
  • Swimming Pool Heater with V Shape Design High Efficiency Evaporator
  • Swimming Pool Heater with V Shape Design High Efficiency Evaporator
  • Swimming Pool Heater with V Shape Design High Efficiency Evaporator
Find Similar Products
  • Overview
  • Product Description
  • Product Parameters
  • Company Profile
Overview

Basic Info.

Model NO.
LAS-KP-V
Transport Package
Carton
Specification
1400*900*1600(mm)
Trademark
Laswim
Origin
China

Product Description


Product Description

LOW TEMPERATURE V-TYPE SWIMMING POOL HEAT PUMP

LASWIM low temperature V-type commercial swimming pool heat pump is specially designed for commercial applications in low temperature areas.

It works with high efficient even under -10ºC(-30ºC EVI heat pump is available). This series heat pump is widely used for pools in hotels, SPA, water parks, gyms, competition pool, etc.

 

Features

1.Intelligent control for constant pool water temperature(max 40ºC)

2.Wide working air temperature range: -10ºC to 45ºC.

3.Anti-corrosion titanium in PVC heat exchanger for durable use.

4.Adopts V-type evaporator, with large heat exchanging surface and great heat absorption.

5.Multiple protections for safe operation and long service life.

6.The housing adopts high-quality galvanized sheet, with strong corrosion resistance.

7.Powerful centralized control and remote control is available for convenient operation and maintenance.

8.Automatic and forced defrosting function.
 

Product Parameters
Model   LAS35-KP-V LAS42-KP-V LAS52-KP-V LAS70-KP-V LAS85-KP-V LAS105-KP-V LAS140-KP-V LAS180-KP-V LAS210-KP-V
Standard heating condition Heating    kW 40.2 48.2 56.3 80.4 96.4 112.6 160.8 192.8 225.2
capacity
COP 5.58 5.58 5.58 5.58 5.58 5.58 5.58 5.58 5.58
Low temperature Heating    kW 28.1 33.7 39.3 56.2 67.4 78.6 112.4 134.8 157.2
heating condition 1 capacity
  COP 3.91 3.91 3.91 3.91 3.91 3.91 3.91 3.91 3.91
Low temperature Heating    kW 23.9 28.7 33.5 47.8 57.4 67 95.6 114.8 134
heating condition 2 capacity
  COP 3.32 3.32 3.32 3.32 3.32 3.32 3.32 3.32 3.32
Cooling   condition Cooling    kW 26.8 32.2 37.5 53.6 64.4 75 107.2 128.8 150
capacity
EER 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2 3.2
Power supply V/ph/Hz 380V/3N/50Hz
Rated input power kW 7.2 8.6 10.1 14.4 17.2 20.2 28.8 34.4 40.4
Rated input current A 12.2 14.6 17.1 24.4 29.2 34.2 48.8 58.4 68.4
Max. Input power kW 11.8 14.2 16.5 23.6 28.4 33 47.2 56.8 66
Max.  Input current A 19.8 23.8 27.7 39.6 47.6 55.4 78.2 95.2 110.8
Max.  outlet water temperature ºC 40
Operating air temperature ºC -10~45
Heat exhanger Titanium in PVC heat exchanger
Max. pressure  MPa 2.8/4.2
Refrigerant  R22/R410A
Noise level dB(A) ≤64 ≤64 ≤65 ≤66 ≤67 ≤68 ≤70 ≤71 ≤71
Water inlet/outlet size mm 50 50 50 50 50 50 65 65 65
Circulating Water flow rate m³/h 8.6 10.4 12.1 17.3 20.7 24.2 34.6 41.5 48.4
Water pressure   drop kPa 40 41 42 63 68 69 52 53 54
Net weight Kg 330 350 410 600 680 750 1000 1050 1180
Net dimension L*W*H mm 1400*900*1600 1400*900*1600 1400*900*1600 1900*1000*1960 1900*1000*1960 1900*1000*1960 1900*2000*1960 1900*2000*1960 1900*2000*1960


Remark:

1.A20/W26 condition :20ºC DB, 15ºC WB, inlet water temperature 26 ºC;
2.A2/W26 condition: 2ºC DB, 1ºC WB,inlet water temperature 26ºC;
3.A-6/W26 condition: -6ºC DB,-7ºC WB,inlet water temperature 26ºC;
4.Cooling condition: 35ºC DB,24ºC WB,inlet water temperature 26 ºC;
Due to the continuous improvement of products, the actual data will be subject to change,please refer to the nameplate.

Swimming Pool Heater with V Shape Design High Efficiency Evaporator

 

Company Profile

Swimming Pool Heater with V Shape Design High Efficiency EvaporatorSwimming Pool Heater with V Shape Design High Efficiency EvaporatorSwimming Pool Heater with V Shape Design High Efficiency EvaporatorSwimming Pool Heater with V Shape Design High Efficiency EvaporatorSwimming Pool Heater with V Shape Design High Efficiency EvaporatorSwimming Pool Heater with V Shape Design High Efficiency EvaporatorSwimming Pool Heater with V Shape Design High Efficiency Evaporator


 

 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier